Low cost, general purpose, industrial ceramic shear ICP® accelerometer, 100 mV/g, top exit, 30-ft integral cable Product Specifications ENGLISHSI Performance Sensitivity (±15 %)100 mV/g10.2 mV/(m/s²)[1]  Measurement Range±50 g±490 m/s²  Frequency Range (±3 dB)30 to 600000 cpm0.5 to 10000 Hz  Resonant Frequency1320 kcpm22 kHz[2]  Broadband Resolution (1)350 µg3434 µm/sec2[2]  Non-Linearity±1 %±1 %[3]  Transverse Sensitivity≤7 %≤7 % Environmental Overload Limit (Shock)5000 g pk49050 m/s² pk  Temperature Range-65 to +250 °F-54 to +121 °C  Enclosure RatingIP68IP68 Electrical Settling Time (within 1% of bias)≤2.0 sec≤2.0 sec  Discharge Time Constant≥0.3 sec≥0.3 sec  Excitation Voltage18 to 28 VDC18 to 28 VDC  Constant Current Excitation2 to 20 mA2 to 20 mA  Output Impedance<150>150><150>150>  Output Bias Voltage8 to 12 VDC8 to 12 VDC  Spectral Noise (10 Hz)8 µg/√Hz78.5 (µm/sec2)/√Hz[2]  Spectral Noise (100 Hz)5 µg/√Hz49.1 (µm/sec2)/√Hz[2]  Spectral Noise (1 kHz)4 µg/√Hz39.2 (µm/sec2)/√Hz[2]  Electrical Isolation (Case)>100000000 Ohm>100000000 Ohm Physical Size - Hex9/16 in14 mm  Size - Height2.5 in64 mm  Weight (with cable)3.5 oz99.3 gm  MountingStudStud  Mounting Thread1/4-28 Female1/4-28 Female[4]  Mounting Torque2 to 5 ft-lb2.7 to 6.8 Nm  Sensing ElementCeramicCeramic  Sensing GeometryShearShear  Housing MaterialStainless SteelStainless Steel  SealingMoldedMolded  Electrical ConnectorMolded Integral CableMolded Integral Cable  Electrical Connection PositionTopTop  Cable Length30 ft9.1 m  Cable TypePolyurethanePolyurethane[5]  All specifications are at room temperature unless otherwise specified. Product Notes [1] Conversion Factor 1g = 9.81 m/s².[2] Typical.[3] Zero-based, least-squares, straight line method.[4] 1/4-28 has no equivalent in S.I. units.[5] Twisted shielded pair.[6] See PCB Declaration of Conformance PS023 or PS060 for details. Accessories: Supplied081A40Mounting Stud(1)ICS-2NIST-traceable single-axis single-point amplitude response calibration at 6000 cpm (100 Hz)(1) Optional Versions: (EX) Hazardous Area Approval- contact factory for specific approvals ENGLISHSI Hazardous Area ApprovalCl I, Div 2, Groups A, B, C, D; ExnL IIC T4, AExnA IIC T4Cl I, Div 2, Groups A, B, C, D; ExnL IIC T4, AExnA IIC T4 Hazardous Area ApprovalEEx nL IIC T4, -40°C<><=121â°c, ii="" 3="">=121â°c,>EEx nL IIC T4, -40°C<><=121â°c, ii="" 3="">=121â°c,> Hazardous Area ApprovalEEx nL IIC T4, -40°C<><=121â°c, ii="" 1="">=121â°c,>EEx nL IIC T4, -40°C<><=121â°c, ii="" 1="">=121â°c,> Hazardous Area ApprovalCl I, Div I, Groups A, B, C, D; Cl II, Div I, Groups E, F, G; Cl III, Div ICl I, Div I, Groups A, B, C, D; Cl II, Div I, Groups E, F, G; Cl III, Div I Hazardous Area ApprovalEx ia IIC T4, AExia IIC, T4Ex ia IIC T4, AExia IIC, T4(LB) Low Bias Voltage ENGLISHSI Output Bias Voltage4.8 to 6.5 4.8 to 6.5 Excitation Voltage12 to 28 12 to 28 Measurement Range±10 ±98 (M) Metric Mount ENGLISHSIAccessories: M081A61Mounting Stud(1)(TO) Temperature Output ENGLISHSI Temperature Output Range+36 to +250 °F+2 to +121 °C Temperature Scale Factor5.56 mV/°F + 32+10 mV/°C Electrical ConnectorMolded Integral CableMolded Integral Cable Electrical Connections (Red)Acceleration OutputAcceleration Output Electrical Connections (Black)GroundGround Electrical Connections (White)Temperature OutputTemperature Output
Low cost, general purpose, industrial ceramic shear ICP® accelerometer, 100 mV/g, top exit, 30-ft integral cable Product Specifications ENGLISHSI Performance Sensitivity (±15 %)100 mV/g10.2 mV/(m/s²)[1]  Measurement Range±50 g±490 m/s²  Frequency Range (±3 dB)30 to 600000 cpm0.5 to 10000 Hz  Resonant Frequency1320 kcpm22 kHz[2]  Broadband Resolution (1)350 µg3434 µm/sec2[2]  Non-Linearity±1 %±1 %[3]  Transverse Sensitivity≤7 %≤7 % Environmental Overload Limit (Shock)5000 g pk49050 m/s² pk  Temperature Range-65 to +250 °F-54 to +121 °C  Enclosure RatingIP68IP68 Electrical Settling Time (within 1% of bias)≤2.0 sec≤2.0 sec  Discharge Time Constant≥0.3 sec≥0.3 sec  Excitation Voltage18 to 28 VDC18 to 28 VDC  Constant Current Excitation2 to 20 mA2 to 20 mA  Output Impedance<150>150><150>150>  Output Bias Voltage8 to 12 VDC8 to 12 VDC  Spectral Noise (10 Hz)8 µg/√Hz78.5 (µm/sec2)/√Hz[2]  Spectral Noise (100 Hz)5 µg/√Hz49.1 (µm/sec2)/√Hz[2]  Spectral Noise (1 kHz)4 µg/√Hz39.2 (µm/sec2)/√Hz[2]  Electrical Isolation (Case)>100000000 Ohm>100000000 Ohm Physical Size - Hex9/16 in14 mm  Size - Height2.5 in64 mm  Weight (with cable)3.5 oz99.3 gm  MountingStudStud  Mounting Thread1/4-28 Female1/4-28 Female[4]  Mounting Torque2 to 5 ft-lb2.7 to 6.8 Nm  Sensing ElementCeramicCeramic  Sensing GeometryShearShear  Housing MaterialStainless SteelStainless Steel  SealingMoldedMolded  Electrical ConnectorMolded Integral CableMolded Integral Cable  Electrical Connection PositionTopTop  Cable Length30 ft9.1 m  Cable TypePolyurethanePolyurethane[5]  All specifications are at room temperature unless otherwise specified. Product Notes [1] Conversion Factor 1g = 9.81 m/s².[2] Typical.[3] Zero-based, least-squares, straight line method.[4] 1/4-28 has no equivalent in S.I. units.[5] Twisted shielded pair.[6] See PCB Declaration of Conformance PS023 or PS060 for details. Accessories: Supplied081A40Mounting Stud(1)ICS-2NIST-traceable single-axis single-point amplitude response calibration at 6000 cpm (100 Hz)(1) Optional Versions: (EX) Hazardous Area Approval- contact factory for specific approvals ENGLISHSI Hazardous Area ApprovalCl I, Div 2, Groups A, B, C, D; ExnL IIC T4, AExnA IIC T4Cl I, Div 2, Groups A, B, C, D; ExnL IIC T4, AExnA IIC T4 Hazardous Area ApprovalEEx nL IIC T4, -40°C<><=121â°c, ii="" 3="">=121â°c,>EEx nL IIC T4, -40°C<><=121â°c, ii="" 3="">=121â°c,> Hazardous Area ApprovalEEx nL IIC T4, -40°C<><=121â°c, ii="" 1="">=121â°c,>EEx nL IIC T4, -40°C<><=121â°c, ii="" 1="">=121â°c,> Hazardous Area ApprovalCl I, Div I, Groups A, B, C, D; Cl II, Div I, Groups E, F, G; Cl III, Div ICl I, Div I, Groups A, B, C, D; Cl II, Div I, Groups E, F, G; Cl III, Div I Hazardous Area ApprovalEx ia IIC T4, AExia IIC, T4Ex ia IIC T4, AExia IIC, T4(LB) Low Bias Voltage ENGLISHSI Output Bias Voltage4.8 to 6.5 4.8 to 6.5 Excitation Voltage12 to 28 12 to 28 Measurement Range±10 ±98 (M) Metric Mount ENGLISHSIAccessories: M081A61Mounting Stud(1)(TO) Temperature Output ENGLISHSI Temperature Output Range+36 to +250 °F+2 to +121 °C Temperature Scale Factor5.56 mV/°F + 32+10 mV/°C Electrical ConnectorMolded Integral CableMolded Integral Cable Electrical Connections (Red)Acceleration OutputAcceleration Output Electrical Connections (Black)GroundGround Electrical Connections (White)Temperature OutputTemperature Output