InnoCal NIST-Traceable Calibration; 10-15-Point, Liquid-in-Glass Thermometer_1207243
Representative image only

InnoCal NIST-Traceable Calibration 10-15 Point Liquid-in-Glass Thermometer

$1,569.75

The price is inclusive of GST

InnoCal NIST-Traceable Calibration ensures your 10-15 point liquid-in-glass (LIG) thermometer meets manufacturer specifications and provides traceability to NIST. Calibration reports support compliance with EPA, USDA, ISO, GLP/GMP, and FDA standards, allowing your thermometers to be used in critical applications immediately without third-party delays.

Product Features

  • NIST-traceable calibration for 10-15 point liquid-in-glass thermometers
  • Direct comparison in high-stability liquid baths using Precision Reference Thermometers (PRTs) and Standard Platinum Resistance Thermometers (SPRTs) with high-precision displays
  • Thermometers inspected for cracks and liquid-column separations before testing
  • Testing range: –80 to 420°C (–176 to 788°F)
  • Calibration at manufacturer’s recommended points or customer-specified points
  • Correction factors provided for convenience
  • Authorized service center for ERTCO brand LIG thermometers in the U.S.
  • Also calibrates LIG thermometers from Brooklyn Thermometer, Miller and Weber, LSW, H-B Instruments, and others
  • All calibration certificates contain as-found and as-left data, estimated measurement uncertainties (EMU’s), and test uncertainty ratios (TUR’s) at no additional cost
  • Traceable to SI units via NIST-maintained national standards
  • Performed in compliance with ANSI Z540, ISO17025, and MIL-STD-45662A
  • FDA compliant
  • InnoCal accredited to ISO/IEC 17025 by A2LA (Certificate 1746.01)
  • Measurements performed at 10 to 15 points between -197°C and 550°C
  • Points generally selected at manufacturer’s specified points; customer-specified points accommodated

Benefits

  • Ensures your LIG thermometer meets manufacturer specifications with NIST-traceable calibration
  • Provides documented traceability for audits and regulatory compliance
  • Reduces delays and costs by receiving calibrated equipment ready-to-use
  • Supports critical applications requiring regular NIST-traceable calibration per ISO, EPA, USDA, GLP/GMP, and FDA standards

Why Choose InnoCal NIST-Traceable Calibration for 10-15 Point Liquid-in-Glass Thermometer?

Receive your LIG thermometer calibrated and ready for use with confidence. InnoCal provides comprehensive reports, traceability, and compliance assurance for accurate temperature measurement applications.