HiTrap NHS-Activated HP Column, 1 x 5 mL_2361428
HiTrap NHS-Activated HP Column, 1 x 5 mL_2361428
HiTrap NHS-Activated HP Column, 1 x 5 mL_2361428
Representative image only

Cytiva HiTrap NHS-Activated HP Column, 1 × 5 mL

$384.10

The price is inclusive of GST

The Cytiva HiTrap NHS-Activated HP Column, 1 × 5 mL (17071701), is a preactivated affinity chromatography column for covalent coupling of ligands containing primary amines. The 5 mL column is packed with NHS-activated Sepharose High Performance medium and supports convenient preparation of customised affinity columns.

Key Features

  • Single prepacked 5 mL column, supplied as a ready-to-use 1 × 5 mL configuration for customised affinity chromatography
  • Designed for primary amine coupling, enabling immobilisation of proteins and other suitable ligands containing primary amino groups
  • NHS-activated Sepharose High Performance medium, providing preactivated chemistry for covalent ligand attachment
  • Approximately 10 µmol NHS groups per mL of medium, providing the activated groups used for ligand coupling
  • 10-atom spacer arm, separating the immobilised ligand from the agarose matrix
  • Fine 34 µm mean particle size, based on highly cross-linked spherical agarose
  • Recommended flow rate of 5 mL/min, with a maximum flow rate of 20 mL/min for the 5 mL column
  • Coupling conditions from pH 6.5 to 9, with coupling possible at room temperature or 4 °C
  • Broad pH stability from 3 to 12, depending on the properties of the coupled ligand
  • Compact 5 mL column bed, measuring 1.6 cm internal diameter × 2.5 cm bed height
  • Column hardware rated to 5 bar, equivalent to 0.5 MPa

Benefits

  • Simplifies preparation of customised affinity columns by providing the activated chromatography medium in a prepacked format.
  • Reduces ligand immobilisation steps by allowing direct coupling through primary amino groups.
  • Supports flexible affinity method development using a user-selected ligand appropriate to the target biomolecule.
  • Provides practical flow characteristics for rapid coupling, washing, and subsequent chromatography workflows.
  • Allows coupling under near-neutral conditions, helping accommodate a broad range of suitable protein ligands.

Why Choose the Cytiva HiTrap NHS-Activated HP Column, 1 × 5 mL (17071701)?

The Cytiva HiTrap NHS-Activated HP 5 mL column combines preactivated NHS chemistry with a convenient prepacked High Performance agarose format for preparing customised affinity columns. Buy from John Morris Group for access to Cytiva chromatography products and technical support for your laboratory workflow.

Over 40,000 Customers Trust John Morris