Artel MVS Multichannel Verification System for Liquid Handling Confidence
A fast, reliable and traceable solution for verifying automated liquid handlers and multichannel pipettes in modern laboratory workflows.

Accurate liquid handling is critical for reliable laboratory results. In workflows involving automated liquid handlers and multichannel pipettes, even small dispensing errors can affect assay performance, reproducibility and data integrity. The Artel MVS Multichannel Verification System helps laboratories verify liquid handling performance quickly, consistently and with traceable documentation.
Volume Verification
Verify dispensed volumes from automated liquid handlers and multichannel pipettes.
Fast Results
Designed to deliver verification results in minutes, helping reduce workflow delays.
Traceable Reporting
Supports traceable verification records for quality, compliance and audit requirements.
Workflow Confidence
Helps laboratories identify performance issues before they affect downstream results.
What is the Artel MVS Multichannel Verification System?
The Artel MVS is a liquid handling verification system designed to measure the dispensed volume performance of automated liquid handling systems and multichannel handheld pipettes. It uses a photometric measurement approach to verify volumes across microplate wells, helping laboratories assess accuracy, precision and channel-to-channel consistency.
Unlike manual gravimetric checks, the MVS is designed for multichannel and plate-based workflows. This makes it particularly useful for laboratories working with high-throughput screening, assay development, biotechnology, pharmaceutical research, clinical testing and regulated quality control environments.
John Morris Group distributes Advanced Instruments liquid handling verification solutions, including the Artel MVS bundles, supporting laboratories that require reliable verification systems for liquid handling performance.

Built for multichannel and automated workflows
Multichannel pipettes and automated liquid handlers are used to dispense many samples at once. While this improves speed and throughput, it also makes verification more important. A single underperforming channel or dispensing head can introduce variation across a plate.
The MVS helps laboratories check whether liquid handling devices are dispensing accurately and consistently across channels, rows, columns and plate formats.
How the MVS verification workflow works
Dispense
The system uses prepared verification solutions and diluent in a microplate format, reducing the need for in-house dye preparation or manual standard curve generation.
Read
The plate reader measures absorbance values in each well and supports volume calculation without requiring traditional weighing methods.
Verify
ArtelWare software calculates accuracy and precision, helping teams review performance by well, row, column, tip or channel.
Why liquid handling verification matters
Liquid handling equipment is often used at the beginning of critical workflows. If volume delivery is inaccurate, the impact may carry through the entire process. This can affect sample preparation, reagent addition, assay performance, result interpretation and reproducibility.
Regular verification helps laboratories identify liquid handling issues before they become larger quality problems. It can also help teams compare performance across instruments, users, protocols and locations.
For laboratories working under quality systems or regulatory expectations, the MVS also supports documentation and audit readiness by creating clear verification records.
Available bundle options from John Morris Group
John Morris Group offers MVS bundle options to suit different laboratory plate formats. Laboratories working primarily with 96-well workflows may choose the 96-well bundle, while laboratories requiring both 96- and 384-well verification can select the expanded 96 and 384-well configuration.
These bundles are designed to provide the core hardware, software and start-up consumables required for liquid handling verification workflows.

Typical bundle components
Certified Artel Plate Reader
The core reading instrument used to measure verification plates and support photometric volume verification.
Calibrator Plate
Supports system verification and traceability as part of the overall MVS workflow.
Plate Shaker & Barcode Reader
Helps streamline plate preparation, mixing, identification and workflow consistency.
ArtelWare Software
Calculates accuracy, precision and summary results for reporting and documentation.
Portable Computer
Supports convenient system control and data management for verification workflows.
MVS Consumables
Customised consumables help laboratories begin verification workflows with the system.
Suitable laboratory applications
The Artel MVS is suitable for laboratories where accurate and reproducible liquid handling is essential.
Learn more from Nova Biomedical
Nova Biomedical provides detailed product information on the Artel MVS Multichannel Verification System, including its workflow, specifications, compliance information and liquid handling verification capabilities.
Visit Nova Biomedical MVS Product PageConclusion
The Artel MVS Multichannel Verification System gives laboratories a practical way to verify liquid handling performance across automated liquid handlers and multichannel pipettes. By supporting fast verification, traceable results and software-driven reporting, the MVS helps laboratories improve confidence in liquid handling accuracy, precision and reproducibility.
Through John Morris Group, laboratories can access Advanced Instruments MVS bundle options for 96-well and 96/384-well verification workflows, supported by a distributor with local experience in laboratory technology solutions.
Strengthen confidence in your liquid handling workflows
Explore Artel MVS bundle options available through John Morris Group for fast, reliable and traceable multichannel liquid handling verification.