HiTrap Chelating HP Columns, 5 × 5 mL_2361114
HiTrap Chelating HP Columns, 5 × 5 mL_2361114
HiTrap Chelating HP Columns, 5 × 5 mL_2361114
HiTrap Chelating HP Columns, 5 × 5 mL_2361114
HiTrap Chelating HP Columns, 5 × 5 mL_2361114
HiTrap Chelating HP Columns, 5 × 5 mL_2361114
HiTrap Chelating HP Columns, 5 × 5 mL_2361114
HiTrap Chelating HP Columns, 5 × 5 mL_2361114
HiTrap Chelating HP Columns, 5 × 5 mL_2361114
HiTrap Chelating HP Columns, 5 × 5 mL_2361114
HiTrap Chelating HP Columns, 5 × 5 mL_2361114
Representative image only

HiTrap Chelating HP Columns, 5 × 5 mL

$1,501.90

The price is inclusive of GST

The HiTrap Chelating HP Columns, 5 × 5 mL (17040903) are prepacked immobilized metal affinity chromatography columns supplied as 5 × 5 mL columns. Each 5 mL column is packed with Chelating Sepharose High Performance medium, with an iminodiacetic acid chelating group, approximately 23 µmol Cu2+/mL medium metal ion capacity and a 34 µm mean particle size. The columns are supplied uncharged and can be charged with a suitable metal ion for purification of proteins and peptides with affinity for metal ions, including histidine-tagged proteins.

Key Features

  • Prepacked Chelating HP column format, supplied as 5 × 5 mL columns for immobilized metal affinity chromatography
  • Uncharged IMAC resin format, ready to charge with the metal ion of choice for optimised selectivity
  • Chelating Sepharose High Performance medium, based on highly cross-linked 6% spherical agarose
  • Iminodiacetic acid chelating group, coupled by stable ether groups via a spacer arm
  • Approximately 12 mg histidine-tagged protein/mL binding capacity, based on pure histidine-tagged protein with Mr approximately 27 600
  • 34 µm mean particle size, supporting high-performance affinity purification in the HiTrap format
  • Flexible operation, suitable for use with a syringe, peristaltic pump or liquid chromatography system such as ÄKTA

Benefits

  • Supports purification of native and recombinant proteins or peptides that show affinity for metal ions.
  • Allows metal ion selection to be optimised for the target protein and purification conditions.
  • Provides a ready-to-use prepacked format that reduces column preparation time.
  • Gives laboratories a 5-column pack for repeated IMAC purification runs or method optimisation.

Why Choose the HiTrap Chelating HP Columns, 5 × 5 mL (17040903)?

Choose the HiTrap Chelating HP Columns, 5 × 5 mL (17040903) when you need uncharged prepacked IMAC columns for purification of proteins and peptides with metal ion affinity. John Morris Group supplies Cytiva HiTrap chromatography columns to Australian laboratories with local quoting and product support.

Over 40,000 Customers Trust John Morris